Complete 500 scfm Vapor Extraction System w/ Oxidizer
POWERFUL! With a small 6’ x 6’ skid assembly, the Compact-THERM is able to extract well vapors at up to 700 cfm flows, thermally destroy at up to 1800F, and allows quick switching from thermal to catalytic mode. Premium features include stainless steel vapor piping, stainless steel water knockout, PLC controls with digital display, color digital chart recorder, and two temperature controllers. Options include: heat exchanger, auto pump for water knockout, blower & motor enclosure, data logger, telemetry, and more!
SOIL-THERM Compact-THERM systems are capable of adding modular Air Strippers, Air Sparge Blowers, Dual-Phase Extraction Blowers (double click for pdf brochure) & more.
Compact-THERM
STANDARD EQUIPMENT
Each Compact-THERM system includes the following: SOIL-THERM Model 2002 Jet-THERM burner & oxidizer, 60 gallon water knockout, particulate filter, manual dilution air valve, manual well vapor valve, vacuum relief valve, positive displacement blower, TEFC motor, belt drive, blower/motor enclosure, discharge silencer, Nema 4 electrical box & controls, flame arrestor, PLC with digital display, error fault message display, UV flame safeguard system, propane/natural gas gas train, temperature controllers (2), digital chart recorder, and burner cooling blower.
INSTRUMENTATION & CONTROLS
The most advanced on the market! Each Compact-Therm system includes:
CALCULATE Compact-THERM FUEL USAGE
At total flows of approximately 500 scfm going into the oxidizer, and the temperature at the exhaust stack is 1400F at influent concentrations are 7,000 ppmv. By calculating the total energy required, then subtracting the VOC energy from the vapors burned, you can determine the approximate fuel requirements and cost when operating a SOIL-THERM system:
SOIL-THERM OPERATING FUEL COST
BTU/hr = (#/hour Air Flow) x (coeff. for air) x (Temp. Rise)
Total BTUs Required = (2250) x (0.24) x (1400-100) = 702,000 btuh
VOC Energy = (2250) x (7,000)/(106) x (0.23/.075) x (12,000 btu/#) = 579,600 btuh
FUEL REQUIRED: 702,000 - 579,600 = 122,400 btus/hour
NATURAL GAS: (122,400 btuh)/(1000 btu/cf) = 122.4 cfh Natural Gas Reqd
APPROX. FUEL COST: (122,400 btu)/ (100,000 btu/therm)x$1.30 = $1.59/hr
Compact-Therm w/Noise Reduction Side Panels. By installing acoustic noise panels around a standard Compact-THERM, noise reduction of approximately 5 dBA may be achieved. SOIL-THERM has the ability to build these types of systems in order to minimize noise in residential areas.

New! Stainless KO & Piping !
Specifications
|
COMPARE FUEL COSTS Compact-THERM: $1.59/hour “OTHER BRANDS”: $10.04/hour Monster Gas Bill ! These hourly supplemental fuel costs represent each thermal oxidizer system processing 500 scfm @ 7000 ppmv VOC’s in thermal mode, 1400F exhaust temp, and natural gas @ $1.30/therm. All fuel costs are estimates, individual results may vary. Call for more details. |
ENERGY EFFICIENT Remediation Technologies

www.soiltherm.com
5310 Derry Ave., Unit C, Agoura Hills, CA 91301 FAX: (818) 706-2145



Since 1990
About SOIL-THERM
Remediation Thermal Systems (super small sizes)
Multi-Phase Remediation Systems
Rental Systems
a Soil-Therm Equipment, Inc, 2002-2005. All rights reserved. Data and information provided in this site are for evaluation purposes only, individual results may vary.
“We currently own three SOIL-THERM mobile dual phase thermal systems, custom built to our specs. These systems provide impressive processing rates, high destruction efficiencies, and are extremely reliable. We’ve used the others, SOIL-THERM is the best and uses at least 50% less fuel!”. Tom Waller, PE, Principal Engr, Holguin Fahan & Assoc.
“SOIL-THERM designed and built a Mobile-THERM system that was impressive to look at and operated using much less fuel than all others we’ve used. The finest equipment at a great price.” Steve Diamond, EnviroTRAC
“It has been my field experience that SOIL-THERM oxidizer systems are as much as 50% more energy efficient than the other conventional oxidizers. Our SOIL-THERM mobile dual phase oxidizer system has been extremely reliable and versatile. Its custom design achieves excellent operation over a wide range of flows and concentrations”. Dan Louks, Vice President, GSA Engineering
“I operate over 30 SVE thermal systems from all manufacturers. Based on my field experience, I have found that SOIL-THERM systems are much more energy efficient and outperform the others by far ! Thery’re also highly reliable and have excellent uptime”. Darren Azarian, Principal, Integral Engineering Services, Inc.


Aerospace Combustion
(818) 706-9875
|
Environmental Business Journal “Industry’s Best in 2003 & 2004” |
“2003 TECHNOLOGY MERIT AWARD... for developing and deploying thermal and catalytic systems with the new Jet-THERM combustion process technology... to achieve virtually 100% destruction of VOC’s from soil-vapor-extractions, multi-phase-extraction, and chlorinate emissions control applications .” Environmental Business Journal, January, 2004
“2004 TECHNOLOGY MERIT AWARD... for implementing advances in its Jet-THERM combustion burner process to destroy methyl tert-butyl ether (MTBE) contaminants recovered in groundwater treated by soil-vapor extraction and multi-phase extracdtion.” Environmental Business Journal, March, 2005